Prev Next Download
TF03      58  1  05P126First Revised Sheet No. 58
TF04                Original Sheet No. 58
TF05Edward C. McMurtrie, Vice President/General Manager
TF06040197021897RP97-136-000        060197
                   GENERAL TERMS AND CONDITIONS
                           (Continued)


2.  MEASUREMENTS AND MEASURING EQUIPMENT (Continued)

    2.1   Unit of Measurement and Basis of Measurement of Gas: (Continued)

          (e) Calibration and Test of Gas Meters: If either Shipper or Paiute
              shall at any time have reason to doubt the accuracy of any
              gauge, measuring device, or other appliance used in measuring
              the gas received or delivered, it shall notify the other in
              writing, and within a reasonable time thereafter the measuring
              device shall be tested in the presence of both parties.

          (f) Correction of Gas Metering Errors: If any measuring device used
              to obtain the quantity of gas received or delivered shall have
              been found on test to be in error by more than two percent
              (2%), the amount of gas which shall have been received or
              delivered during a period commencing not more than thirty (30)
              days prior to the date of notification mentioned in Section
              2.1(e) hereof shall be recalculated and corrected back to a
              zero percent (0%) error.

          (g) The cutoff for the closing of measurement is five (5) business
              days after the business month. In cases where actual data is
              missing or late, Paiute will use an estimate. Paiute will treat
              any difference between actual data and estimated data as a
              prior period adjustment.

          (h) Paiute will treat measurement prior period adjustments by
              taking it back to the production month. A meter adjustment
              becomes a prior period adjustment after the fifth (5th)
              business day following the business month. For reporting
              measurement prior period adjustments, Paiute will report it
              using a restated line item with new total quantity for the day
              and the month. Measurement corrections will be processed within
              six (6) months of the production month with a (3) month
              rebuttal period. This standard shall not apply in the case of
              deliberate omission or misrepresentation or mutual mistake of
              fact. Parties' other statutory or contractual rights shall not
              otherwise be dismissed by this standard.


Prev Next Download